A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our [...] basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions.
A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our [...] basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions.
Über den Autor
I am a highly enthusiastic professional always trying hard to fulfill my goals to grow professionally and spritually which is indispensable for the well being of human kind. born and grown up in a beautiful town Bahirdar, Ethiopia. Currently i am a lecturer in analytical chemistry,at one of the oldest universities in Ethiopia, Haremaya university.
Details
| Erscheinungsjahr: | 2011 |
|---|---|
| Genre: | Ratgeber, Sachbuch |
| Rubrik: | Ratgeber |
| Thema: | Briefe, Bewerbungen, Wiss. Arbeiten, Rhetorik |
| Medium: | Taschenbuch |
| Inhalt: | 60 S. |
| ISBN-13: | 9783846528778 |
| ISBN-10: | 3846528773 |
| Sprache: | Englisch |
| Einband: | Kartoniert / Broschiert |
| Autor: |
Hudie, Shemsia Mohamed
Moges, Ghirma |
| Hersteller: | LAP LAMBERT Academic Publishing |
| Verantwortliche Person für die EU: | OmniScriptum GmbH & Co. KG, Bahnhofstr. 28, D-66111 Saarbrücken, info@akademikerverlag.de |
| Maße: | 220 x 150 x 4 mm |
| Von/Mit: | Shemsia Mohamed Hudie (u. a.) |
| Erscheinungsdatum: | 02.11.2011 |
| Gewicht: | 0,107 kg |